Description
If the interpretation of fluorescent penetrant testing requires specific lighting conditions, the previous steps, in
particular the rinsing of the parts, must also meet certain requirements. The irradiance on the surface of the part must be ≥ 300 µW/cm² (NF EN ISO 3059). SOFRANEL proposes to replace the UV-A neon lights usually used by LED tubes compliant with NF EN ISO 3452-1 offering better lighting conditions and lower maintenance costs. Waterproof (IP 67), powerful and robust, the modelsT-LED8andT-LED16will become your new references in the optimization of your control conditions.