High frequency transducers

Description

These are single-element transducers used in direct contact or immersion technique, designed to generate frequencies starting from 20 MHz and beyond. These transducers are available in fused silica delay line technology.

Benefits:

  • Wide bandwidth and high damping ensure excellent resolution.
  • Short wavelengths for improved defect detection.
  • Focusing on very small beam diameters.
  • Frequency range from 20-150 MHz (contact us for higher frequencies).

Benefits:

  • High resolution for detecting defects such as micro-cracks or micro-porosities.
  • C-scan imaging of surface-breaking cracks or irregularities.
  • Thickness measurement of parts from 0.025 mm (steel equivalent).
  • Inspection of technical ceramics and other materials. Material analysis.
  • Acoustic microscopy.

High-frequency contact transducers

  • Integrated fused silica delay line for evaluating defect severity, material analysis, or thickness measurements using the direct contact inspection method.
  • Three different delay line types available to optimize signal echoes.
  • Standard transducers come with radial output via Microdot connector.
Direct contact high-frequency transducer diagram Delay line type A B C
SL 18 mm 21 mm 25 mm
FL 9 mm 11 mm 21 mm
FS 9 mm 11 mm 16 mm
Frequency MHz Element diameter (mm) Element diameter (inches) Delay line length (µs) Transducer reference
20 6 mm
6 mm
6 mm
0.25″
0.25″
0.25″
4.25
4.25
2.5
VF 202-FL
VF 202-SL
VF 202-FS
30 6 mm
6 mm
6 mm
0.25″
0.25″
0.25″
4.25
4.25
2.5
VF 302-FL
VF 302-SL
VF 302-FS
50 6 mm
6 mm
6 mm
3 mm
3 mm
3 mm
0.25″
0.25″
0.25″
0.125″
0.125″
0.125″
4.25
4.25
2.5
4.25
4.25
2.5
VF 502-FL
VF 502-SL
VF 502-FS
VF 501-FL
VF 501-SL
VF 501-FS
75 3 mm
3 mm
0.125″
0.125″
4.25
2.5
VF 751-FL
VF 751-FS
100 3 mm
3 mm
0.125″
0.125″
4.25
2.5
VF 1001-FL
VF 1001-FS
125 3 mm 0.125″ 2.5 VF 1251-FS
150 3 mm 0.125″ 2.5 VF 1501-FS
Cable for all LEMO1 / Microdot transducers reference LCM 74-2 or BNC / Microdot reference 2124-2. For frequencies from 30 MHz, we recommend short cables with double shielding and very low impedance. Contact us

High-frequency transducers, immersion, standard housing

  • Integrated fused silica delay line for frequencies above 30 MHz. For frequencies below 30 MHzdelay lines are epoxy.
  • Focused transducers using optical-quality lenses.
  • High frequency combined with a compact housing.
Frequency MHz Element diameter (mm) Element diameter (inches) Delay line length (µs) Focal length Transducer reference
20 6 mm
6 mm
6 mm
6 mm
0.25″
0.25″
0.25″
0.25″
4.25
2.5
4.25
4.25
Flat
19 mm
32 mm
51 mm
VF 401
VF 402
VF 403
VF 404
30 6 mm
6 mm
6 mm
6 mm
0.25″
0.25″
0.25″
0.25″
4.25
2.5
4.25
4.25
Flat
19 mm
32 mm
51 mm
VF 405
VF 406
VF 407
VF 408
50 6 mm
6 mm
6 mm
6 mm
0.25″
0.25″
0.25″
0.25″
4.25
2.5
4.25
2.5
Flat
19 mm
32 mm
13 mm
VF 409
VF 410
VF 411
VF 412
75 6 mm 0.25″ 2.5 13 mm VF 413
100 6 mm 0.25″ 2.5 13 mm VF 414
Cable for all these BNC / Microdot transducers. Contact us for other lengths or impedances.
* Transducers designed to generate surface waves in steel, titanium, and similar high-speed materials.